Stormwater Bmp Sizing: underground_detention

Stormwater Best Management Practice (BMP) and green infrastructure sizing criteria, pollutant removal efficiencies, and design parameters for 12 BMP types per EPA, International Stormwater BMP Database 2020, MDE, Virginia DEQ, and Minnesota Stormwater Manual

Civil Engineeringbmp_type: underground_detention2 rows
bmp typebmp variantTSS removal pct (%)applicable HSGdesign storm in (in)expected lifespan years (years)maintenance frequencymax contributing drainage acres (acres)media depth in (in)nitrogen removal pct (%)notespeak flow reduction pct (%)phosphorus removal pct (%)ponding depth in (in)relative cost indexsizing ratio bmp to drainage area (dimensionless)underdrain requiredvolume reduction pct (%)
underground_detentionclosed_bottom20A,B,C,D130annually5005Closed bottom system: no infiltration. Peak flow control only. TSS removal via settling in large chambers. Requires outlet structure.70100very_high0.02no10
underground_detentionmodular_arch20A,B,C,D130annually10005Large modular arch underground detention. No WQ treatment. Peak flow attenuation only. Very high cost.80100very_high0.02no10