Civil Engineeringbmp_type: dry_detention3 rows
bmp typebmp variantTSS removal pct (%)applicable HSGdesign storm in (in)expected lifespan years (years)maintenance frequencymax contributing drainage acres (acres)media depth in (in)nitrogen removal pct (%)notespeak flow reduction pct (%)phosphorus removal pct (%)ponding depth in (in)relative cost indexsizing ratio bmp to drainage area (dimensionless)underdrain requiredvolume reduction pct (%)
dry_detentionenhanced_extended_detention65A,B,C,D130annually5002040-hr EDT design. TSS 65% per Maryland ESD manual level-2. Enhanced settling with micropool.753018low0.02no20
dry_detentionextended_detention50A,B,C,D130annually50015Sized for 24-hr extended detention of WQv (1 in design storm). TSS 50% for 24-hr EDT per NJ BMP Manual 2004. Minimal P removal. Primarily peak flow control.702012low0.02no15
dry_detentionmicropool_extended_detention70A,B,C,D0.7530annually50025Micropool EDT pond. Permanent pool 1-10% of total pool volume prevents re-suspension. Improved TSS performance 70% vs standard EDT 50%.753518low0.02no20