| bmp type | bmp variant | TSS removal pct (%) | applicable HSG | design storm in (in) | expected lifespan years (years) | maintenance frequency | max contributing drainage acres (acres) | media depth in (in) | nitrogen removal pct (%) | notes | peak flow reduction pct (%) | phosphorus removal pct (%) | ponding depth in (in) | relative cost index | sizing ratio bmp to drainage area (dimensionless) | underdrain required | volume reduction pct (%) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| dry_detention | enhanced_extended_detention | 65 | A,B,C,D | 1 | 30 | annually | 50 | 0 | 20 | 40-hr EDT design. TSS 65% per Maryland ESD manual level-2. Enhanced settling with micropool. | 75 | 30 | 18 | low | 0.02 | no | 20 |
| dry_detention | extended_detention | 50 | A,B,C,D | 1 | 30 | annually | 50 | 0 | 15 | Sized for 24-hr extended detention of WQv (1 in design storm). TSS 50% for 24-hr EDT per NJ BMP Manual 2004. Minimal P removal. Primarily peak flow control. | 70 | 20 | 12 | low | 0.02 | no | 15 |
| dry_detention | micropool_extended_detention | 70 | A,B,C,D | 0.75 | 30 | annually | 50 | 0 | 25 | Micropool EDT pond. Permanent pool 1-10% of total pool volume prevents re-suspension. Improved TSS performance 70% vs standard EDT 50%. | 75 | 35 | 18 | low | 0.02 | no | 20 |