Seismic qualification requirements for nuclear power plant safety-related equipment per IEEE 344-2013, NRC Regulatory Guide 1.100 Rev.4, and NRC RG 1.60/1.61. Covers equipment seismic categories (Class 1E, Category I/II, non-seismic), test levels (OBE/SSE in g), Required Response Spectra (RRS) frequency ranges, damping ratios, fragility parameters (median capacity Am, randomness beta_R, uncertainty beta_U, HCLPF) by equipment class (switchgear, MCC, I&C panels, diesel generators, pumps, valves, piping, tanks), and anchorage design requirements.

Nuclear Engineeringequipment_category: valve_active2 rows
equipment categoryqualification parameterdescriptionnotesparameter unitparameter value maxparameter value minparameter value typicalqualification methodseismic category
valve_activefragility_median_capacity_Am_gMedian seismic capacity for motor-operated valves (MOVs) and solenoid valves.Valves are mechanically simple; high structural capacity. Actuator and position switch may govern. MOVs typically very robust.g612.5fragility_analysisClass_1E_Seismic_Category_I
valve_activehclpf_capacity_gHCLPF for safety-related active valves. Generally high due to simple robust construction.Actuator failure modes evaluated separately; solenoid valves may have lower fragility than motor-operated valves.g30.51.2fragility_analysisClass_1E_Seismic_Category_I