Nuclear Seismic Qualification: diesel_generator

Seismic qualification requirements for nuclear power plant safety-related equipment per IEEE 344-2013, NRC Regulatory Guide 1.100 Rev.4, and NRC RG 1.60/1.61. Covers equipment seismic categories (Class 1E, Category I/II, non-seismic), test levels (OBE/SSE in g), Required Response Spectra (RRS) frequency ranges, damping ratios, fragility parameters (median capacity Am, randomness beta_R, uncertainty beta_U, HCLPF) by equipment class (switchgear, MCC, I&C panels, diesel generators, pumps, valves, piping, tanks), and anchorage design requirements.

Nuclear Engineeringequipment_category: diesel_generator2 rows
equipment categoryqualification parameterdescriptionnotesparameter unitparameter value maxparameter value minparameter value typicalqualification methodseismic category
diesel_generatorfragility_median_capacity_Am_gMedian seismic capacity for diesel generator as emergency power supply.Large heavy equipment with low frequency; typically anchorage governs. Am reflects combined structural+functional capacity.g40.81.8fragility_analysisClass_1E_Seismic_Category_I
diesel_generatorhclpf_capacity_gHCLPF for diesel generator. Fuel system and cooling components may govern over structural.Typically HCLPF > 0.5g for modern qualified DG installations with rigid anchorage.g20.40.9fragility_analysisClass_1E_Seismic_Category_I

This is a sample. Search the full nuclear seismic qualification dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE

Related data