Nuclear Seismic Qualification: pump_active
Seismic qualification requirements for nuclear power plant safety-related equipment per IEEE 344-2013, NRC Regulatory Guide 1.100 Rev.4, and NRC RG 1.60/1.61. Covers equipment seismic categories (Class 1E, Category I/II, non-seismic), test levels (OBE/SSE in g), Required Response Spectra (RRS) frequency ranges, damping ratios, fragility parameters (median capacity Am, randomness beta_R, uncertainty beta_U, HCLPF) by equipment class (switchgear, MCC, I&C panels, diesel generators, pumps, valves, piping, tanks), and anchorage design requirements.
| equipment category | qualification parameter | description | notes | parameter unit | parameter value max | parameter value min | parameter value typical | qualification method | seismic category |
|---|---|---|---|---|---|---|---|---|---|
| pump_active | fragility_median_capacity_Am_g | Median seismic capacity for Class 1E pumps (ECCS, RHR, charging pumps). | Heavy rotating equipment; structural failure unlikely before ~3–5g. Functional failure (seal leak, bearing damage, vibration) governs at lower levels. | g | 5 | 0.8 | 2 | fragility_analysis | Class_1E_Seismic_Category_I |
| pump_active | hclpf_capacity_g | HCLPF for safety-related pumps. Governed by functional operability (seal/bearing) not structural. | Well-qualified pumps with horizontal/vertical configurations tested per IEEE 344 typically achieve HCLPF > 1.0g. | g | 2.5 | 0.4 | 1 | fragility_analysis | Class_1E_Seismic_Category_I |
This is a sample. Search the full nuclear seismic qualification dataset and 300+ more by creating a free account and accessing the database.
Get started for FREERelated data
anchorage_design2 rowsclass_1e_active_electrical3 rowsclass_1e_passive_structural3 rowsdiesel_generator2 rowselectrical_switchgear3 rowsinstrumentation_control_panel2 rowsmotor_control_center3 rowsnon_seismic1 rowpiping_large1 rowpiping_small1 rowqualification_by_analysis2 rowsqualification_by_experience1 row