Seismic qualification requirements for nuclear power plant safety-related equipment per IEEE 344-2013, NRC Regulatory Guide 1.100 Rev.4, and NRC RG 1.60/1.61. Covers equipment seismic categories (Class 1E, Category I/II, non-seismic), test levels (OBE/SSE in g), Required Response Spectra (RRS) frequency ranges, damping ratios, fragility parameters (median capacity Am, randomness beta_R, uncertainty beta_U, HCLPF) by equipment class (switchgear, MCC, I&C panels, diesel generators, pumps, valves, piping, tanks), and anchorage design requirements.

Nuclear Engineeringequipment_category: qualification_by_test1 row
equipment categoryqualification parameterdescriptionnotesparameter unitparameter value maxparameter value minparameter value typicalqualification methodseismic category
qualification_by_testtrs_vs_rrs_envelope_pctMaximum allowable deficit of Test Response Spectrum (TRS) below Required Response Spectrum (RRS). TRS must envelope RRS.IEEE 344-2013 Sec 6.3.4: TRS shall envelop or equal RRS. A 10% deficit may be acceptable if peak response in that frequency range is demonstrated to be acceptable.percent1005testClass_1E_Seismic_Category_I