Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Parallel-flow

0.75 1.5 to 1.00 1.5

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Parallel-flow10 rowsPage 4 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Parallel-flow0.75 1.50.750.51.5
Parallel-flow0.75 2.00.750.542
Parallel-flow0.75 2.50.750.552.5
Parallel-flow0.75 3.00.750.563
Parallel-flow0.75 4.00.750.574
Parallel-flow0.75 5.00.750.575
Parallel-flow1.00 0.0100
Parallel-flow1.00 0.510.250.5
Parallel-flow1.00 1.010.391
Parallel-flow1.00 1.510.451.5

What else is in Engineering Database