0.50 1.0 to 0.75 1.0

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Parallel-flow10 rowsPage 3 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Parallel-flow0.50 1.00.50.481
Parallel-flow0.50 1.50.50.571.5
Parallel-flow0.50 2.00.50.612
Parallel-flow0.50 2.50.50.642.5
Parallel-flow0.50 3.00.50.653
Parallel-flow0.50 4.00.50.664
Parallel-flow0.50 5.00.50.675
Parallel-flow0.75 0.00.7500
Parallel-flow0.75 0.50.750.280.5
Parallel-flow0.75 1.00.750.421