Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Parallel-flow

1.00 2.0 to 1.00 5.0

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Parallel-flow5 rowsPage 5 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Parallel-flow1.00 2.010.472
Parallel-flow1.00 2.510.492.5
Parallel-flow1.00 3.010.493
Parallel-flow1.00 4.010.54
Parallel-flow1.00 5.010.55

What else is in Engineering Database

Related data