Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Parallel-flow

0.25 0.5 to 0.50 0.5

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Parallel-flow10 rowsPage 2 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Parallel-flow0.25 0.50.250.350.5
Parallel-flow0.25 1.00.250.551
Parallel-flow0.25 1.50.250.671.5
Parallel-flow0.25 2.00.250.732
Parallel-flow0.25 2.50.250.772.5
Parallel-flow0.25 3.00.250.783
Parallel-flow0.25 4.00.250.794
Parallel-flow0.25 5.00.250.85
Parallel-flow0.50 0.00.500
Parallel-flow0.50 0.50.50.310.5

What else is in Engineering Database