library reading rooms to office general

Structural design loads — live loads, dead loads, special loads per ASCE 7 and IBC codes for various occupancy types

Civil Engineeringload category: FLOOR LIVE9 rowsPage 4 of 6
load categoryload idconcentrated kN (kN)concentrated lbs (lbs)namereduciblestandardsubcategoryuniform kPa (kPa)uniform psf (psf)
FLOOR LIVElibrary reading rooms4.4481,000Libraries — reading roomsyesASCE 7-22 Table 4.3-1library2.87360
FLOOR LIVElibrary stack rooms4.4481,000Libraries — stack roomsnoASCE 7-22 Table 4.3-1library7.182150
FLOOR LIVEmanufacturing heavy13.3443,000Manufacturing — heavynoASCE 7-22 Table 4.3-1manufacturing11.97250
FLOOR LIVEmanufacturing light8.8962,000Manufacturing — lightyesASCE 7-22 Table 4.3-1manufacturing5.985125
FLOOR LIVEmercantile first floor4.4481,000Mercantile — first flooryesASCE 7-22 Table 4.3-1mercantile4.788100
FLOOR LIVEmercantile retail ground4.4481,000Mercantile — retail stores, ground flooryesASCE 7-22 Table 4.3-1mercantile4.788100
FLOOR LIVEmercantile upper floors4.4481,000Mercantile — upper floorsyesASCE 7-22 Table 4.3-1mercantile3.59175
FLOOR LIVEoffice corridors above first8.8962,000Offices — corridors above first flooryesASCE 7-22 Table 4.3-1office3.8380
FLOOR LIVEoffice general8.8962,000Offices — generalyesASCE 7-22 Table 4.3-1office2.39450