Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Design Loads: FLOOR LIVE

office lobbies to restaurant kitchen

Structural design loads — live loads, dead loads, special loads per ASCE 7 and IBC codes for various occupancy types

Civil Engineeringload category: FLOOR LIVE9 rowsPage 5 of 6
load categoryload idnamereduciblestandardsubcategoryuniform kPa (kPa)uniform psf (psf)
FLOOR LIVEparking garage heavyParking garages — trucks and busesnoASCE 7-22 Table 4.3-1parking11.97250
FLOOR LIVEparking garage passengerParking garages — passenger vehicles onlyyesASCE 7-22 Table 4.3-1parking1.91540
FLOOR LIVEresidential habitableResidential — habitable attics and sleeping areasyesASCE 7-22 Table 4.3-1residential1.43630
FLOOR LIVEresidential otherResidential — all other areas except stairs and balconiesyesASCE 7-22 Table 4.3-1residential1.91540
FLOOR LIVEresidential sleepingResidential — sleeping areasyesASCE 7-22 Table 4.3-1residential1.43630
FLOOR LIVEresidential uninhabitable attic noneResidential — uninhabitable attics without storageyesASCE 7-22 Table 4.3-1residential0.47910
FLOOR LIVEresidential uninhabitable attic storageResidential — uninhabitable attics with storageyesASCE 7-22 Table 4.3-1residential0.95820
FLOOR LIVErestaurant diningRestaurants — dining roomsnoASCE 7-22 Table 4.3-1restaurant4.788100
FLOOR LIVErestaurant kitchenRestaurants — kitchensyesASCE 7-22 Table 4.3-1restaurant1.91540

What else is in Engineering Database

Related data