Design Loads: DEAD WEIGHT
mep plumbing allowance to metal steel
Structural design loads — live loads, dead loads, special loads per ASCE 7 and IBC codes for various occupancy types
| load category | load id | name | standard | subcategory | weight kN m3 | weight kPa | weight pcf | weight psf |
|---|---|---|---|---|---|---|---|---|
| DEAD WEIGHT | mep plumbing allowance | Plumbing piping allowance | Engineering reference | ceiling mep | — | 0.096 | — | 2 |
| DEAD WEIGHT | mep sprinkler piping | Fire sprinkler piping | Engineering reference | ceiling mep | — | 0.096 | — | 2 |
| DEAD WEIGHT | mep total allowance | Total MEP allowance (typical office) | Engineering reference | ceiling mep | — | 0.479 | — | 10 |
| DEAD WEIGHT | metal aluminum | Aluminum | ASCE 7-22 C3 | metal | 26.714 | — | 170 | — |
| DEAD WEIGHT | metal brass bronze | Brass and bronze | ASCE 7-22 C3 | metal | 82.341 | — | 524 | — |
| DEAD WEIGHT | metal cast iron | Cast iron | ASCE 7-22 C3 | metal | 70.713 | — | 450 | — |
| DEAD WEIGHT | metal copper | Copper | ASCE 7-22 C3 | metal | 87.37 | — | 556 | — |
| DEAD WEIGHT | metal lead | Lead | ASCE 7-22 C3 | metal | 111.569 | — | 710 | — |
| DEAD WEIGHT | metal stainless steel | Stainless steel | Engineering reference | metal | 77.627 | — | 494 | — |
| DEAD WEIGHT | metal steel | Steel, structural | ASCE 7-22 C3 | metal | 76.999 | — | 490 | — |
What else is in Engineering Database
Iron Engine ↗Engineering AI at ironengine.ai
AI built for engineering. Searches the engineering database, performs calculations, gives source-backed engineering insights.
Get started for free ↗Reference Data375 engineering tablesMaterial properties, pipe and shape dimensions, code tables, and electrical ratings across mechanical, civil, chemical, electrical, materials, and manufacturing engineering.
Browse dataCalculatorsDeterministic engineering calculatorsSizing, checking, and conversion tools that run against the reference tables. Inputs are code-compliant, outputs are traceable to the source standard.
Browse calculators