Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Design Loads: DEAD WEIGHT

metal zinc to roofing wood shingle

Structural design loads — live loads, dead loads, special loads per ASCE 7 and IBC codes for various occupancy types

Civil Engineeringload category: DEAD WEIGHT9 rowsPage 7 of 10
load categoryload idnamestandardsubcategoryweight kPaweight psf
DEAD WEIGHTroofing asphalt shingleAsphalt shinglesEngineering referenceroofing0.122.5
DEAD WEIGHTroofing built up 3plyBuilt-up roofing, 3-plyEngineering referenceroofing0.0721.5
DEAD WEIGHTroofing built up gravelBuilt-up roofing, 3-ply with gravelEngineering referenceroofing0.2635.5
DEAD WEIGHTroofing clay tileClay tile roofingEngineering referenceroofing0.6714
DEAD WEIGHTroofing concrete tileConcrete tile roofingEngineering referenceroofing0.47910
DEAD WEIGHTroofing metal standing seamMetal roofing, standing seamEngineering referenceroofing0.0721.5
DEAD WEIGHTroofing single ply membraneSingle-ply membrane (TPO/EPDM/PVC)Engineering referenceroofing0.0240.5
DEAD WEIGHTroofing slateSlate roofingEngineering referenceroofing0.47910
DEAD WEIGHTroofing wood shingleWood shinglesEngineering referenceroofing0.1443