Aashto Load Factors: STRENGTH IV

AASHTO LRFD Bridge Design Specification load factors and load combinations per Table 3.4.1-1 (9th Edition 2020) — Strength I-V, Service I-IV, Fatigue I-II, Extreme Event I-II

Civil Engineeringlimit state: STRENGTH IV1 row
limit statedc max (dimensionless)dc min (dimensionless)dw max (dimensionless)dw min (dimensionless)standardtu cr sh max (dimensionless)tu cr sh min (dimensionless)wa (dimensionless)
STRENGTH IV1.50.91.50.65AASHTO LRFD 9th Ed Table 3.4.1-11.20.51