Aashto Load Factors: EXTREME EVENT I

AASHTO LRFD Bridge Design Specification load factors and load combinations per Table 3.4.1-1 (9th Edition 2020) — Strength I-V, Service I-IV, Fatigue I-II, Extreme Event I-II

Civil Engineeringlimit state: EXTREME EVENT I1 row
limit statedc max (dimensionless)dc min (dimensionless)dw max (dimensionless)dw min (dimensionless)eq (dimensionless)ll im symbolicstandardtu cr sh max (dimensionless)wa (dimensionless)
EXTREME EVENT I1.250.91.50.651gamma EQAASHTO LRFD 9th Ed Table 3.4.1-111