Part of Engineering Database. 375 reference tables, deterministic calculators, and Engineering AI. Sign up free
Home/Compare/Nickel Alloy/ATI HB-2 vs ATI Moly Permalloy (80Ni-4.4Mo-Fe soft magnetic alloy, annealed)

ATI HB-2 vs ATI Moly Permalloy (80Ni-4.4Mo-Fe soft magnetic alloy, annealed)

Property comparison of ATI HB-2 and ATI Moly Permalloy (80Ni-4.4Mo-Fe soft magnetic alloy, annealed), both nickel alloy.

Nickel Alloy4 compared properties
PropertyATI HB-2ATI Moly Permalloy (80Ni-4.4Mo-Fe soft magnetic alloy, annealed)Difference
Yield strength351 MPa338 MPa-4%
Tensile strength758 MPa682 MPa-10%
Elongation45 %32 %-29%
Density9,210 kg/m³8,250 kg/m³-10%

Difference is ATI Moly Permalloy (80Ni-4.4Mo-Fe soft magnetic alloy, annealed) relative to ATI HB-2. Values are taken from the representative row of each material; both materials may have multiple heat treatments or conditions on their individual pages.

Identification

ATI HB-2
grade
Ni-Mo (N10665)
standard
ASTM B335
heat treatment
Annealed (bar)
ATI Moly Permalloy (80Ni-4.4Mo-Fe soft magnetic alloy, annealed)
grade
UNS N14080
standard
ATI Technical Data Sheet
heat treatment
Magnetic field anneal (controlled cooling to develop permeability)

What else is in Engineering Database

Related comparisons

View each material