Tube Bundle Layout: triangular_1.33

Tube bundle layout constants (K1, n1) for shell-and-tube heat exchanger design — square and triangular pitch at various tube passes per Coulson & Richardson Table 12.3

Mechanical Engineeringpitch_type: triangular_1.333 rows
pitch typetube passesK1 (dimensionless)descriptionn1 (dimensionless)pitch ratio (dimensionless)
triangular_1.3310.319Triangular pitch pt=1.33do; 1 tube pass; Db=do*(Nt/K1)^(1/n1)2.1421.33
triangular_1.3320.249Triangular pitch pt=1.33do; 2 tube passes2.2071.33
triangular_1.3340.175Triangular pitch pt=1.33do; 4 tube passes2.2851.33