Tube Bundle Layout: triangular_1.25

Tube bundle layout constants (K1, n1) for shell-and-tube heat exchanger design — square and triangular pitch at various tube passes per Coulson & Richardson Table 12.3

Mechanical Engineeringpitch_type: triangular_1.253 rows
pitch typetube passesK1 (dimensionless)descriptionn1 (dimensionless)pitch ratio (dimensionless)
triangular_1.2510.319Triangular pitch pt=1.25do; 1 tube pass; Db=do*(Nt/K1)^(1/n1)2.1421.25
triangular_1.2520.249Triangular pitch pt=1.25do; 2 tube passes2.2071.25
triangular_1.2540.175Triangular pitch pt=1.25do; 4 tube passes2.2851.25

This is a sample. Search the full tube bundle layout dataset and 300+ more by creating a free account and accessing the database.