Thermoelectric Module Performance: two_stage_cascade

Thermoelectric module (TEC/TEG) performance — Peltier cooler COP, cooling capacity, and voltage at various delta-T and hot-side temperatures, plus thermoelectric material properties (ZT, Seebeck coefficient)

Mechanical Engineeringmodule_category: two_stage_cascade3 rows
module categoryoperating pointCOPImax A (A)Qmax W (W)Vmax V (V)ZTcooling capacity W (W)current A (A)delta T C (C)delta Tmax C (C)hot side temp C (C)input power W (W)materialmodule size mmnotesvoltage V (V)
two_stage_cascade27#00.441830.50.818301002745Bi2Te340x40Two-stage (cascade) module: lower stage 40x40mm. Upper stage smaller. dT=0, Th=300K. Qmax limited by upper (cold) stage. COP significantly lower than single-stage due to series power stacking.15
two_stage_cascade27#100041830.50.8041001002775Bi2Te340x40dT=dTmax=100K at Th=300K for two-stage cascade. Zero net cooling.18.8
two_stage_cascade27#200.2441830.50.812.63.5201002752.5Bi2Te340x40dT=20K, Th=300K, two-stage cascade.15

This is a sample. Search the full thermoelectric module performance dataset and 300+ more by creating a free account and accessing the database.