Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Tema Standards: tube dimension

tube 7-8 BWG15 to tube 7-8 BWG20

TEMA Standards 10th Edition — tube dimensions (BWG wall thickness), tube material applicability, type designations (front end, shell, rear end, TEMA class), shell thickness minimums, baffle-shell clearances, and nozzle alignment tolerances for shell-and-tube heat exchanger design

Mechanical Engineeringrecord type: tube dimension5 rowsPage 8 of 8
record typerecord idbwg (BWG)standardtube od displaytube od in (in)wall thickness in (in)
tube dimensiontube 7-8 BWG1515TEMA Standards 10th Ed.7/80.8750.072
tube dimensiontube 7-8 BWG1616TEMA Standards 10th Ed.7/80.8750.065
tube dimensiontube 7-8 BWG1717TEMA Standards 10th Ed.7/80.8750.058
tube dimensiontube 7-8 BWG1818TEMA Standards 10th Ed.7/80.8750.049
tube dimensiontube 7-8 BWG2020TEMA Standards 10th Ed.7/80.8750.035