Explore the Engineering Database more efficiently by signing up for free. Sign up free

K4-Formula — Pier Scour

Scour Type
Pier Scour
Factor Name
K4 Formula
Condition
D50>=0.007 Ft and D95>=0.066 ft; VR=V1/Vc50; Min K4=0.4
Factor Description
Armoring/sediment Gradation Correction K4
Factor Value
0.4*(VR)^0.15
PIER_SCOUR — factor name K4_formula · condition D50>=0.007 ft and D95>=0.066 ft; VR=V1/Vc50; min K4=0.4 · factor value 0.4*(VR)^0.15 · factor description Armoring/sediment gradation correction K4 | Scour Design Parameters | Engineering Database