K4-Formula — Pier Scour
- Scour Type
- Pier Scour
- Factor Name
- K4 Formula
- Condition
- D50>=0.007 Ft and D95>=0.066 ft; VR=V1/Vc50; Min K4=0.4
- Factor Description
- Armoring/sediment Gradation Correction K4
- Factor Value
- 0.4*(VR)^0.15