K1-Sharp-Nose — Pier Scour
- Scour Type
- Pier Scour
- Factor Name
- K1 Sharp Nose
- Condition
- Sharp Nose (triangular) Pier
- Factor Description
- Pier Nose Shape Correction Factor K1
- Factor Value
- 0.9
- Factor Value Numeric (dimensionless)
- 0.9