Retaining Wall Type Selection: sheet_pile

Retaining wall type selection decision matrix — 14 wall types across 7 structural categories (gravity, cantilever, MSE, sheet pile, soldier pile, in-situ soil nail, in-situ secant/diaphragm). Each record gives: practical height range, foundation requirements, backfill requirements, typical batter, relative cost index (1=lowest to 6=highest), construction speed, right-of-way requirements, aesthetics rating, seismic performance, drainage requirements, and typical applications. Sources: FHWA-NHI-07-071, AASHTO LRFD 9th Ed Sec 11, NAVFAC DM-7.2, Coduto Foundation Design 3rd Ed Ch.17, USACE EM 1110-2-2504.

Civil Engineeringwall_category: sheet_pile2 rows
wall categorywall typeaesthetics ratingbackfill requirementbatter typicalconstruction speeddrainage requirementfoundation requirementheight max ft (ft)height max m (m)height min ft (ft)height min m (m)notesrelative cost index (dimensionless)row requirementseismic performancetypical applications
sheet_pilesheet_pile_anchoredpoor — corrugated steel faceany — retains in-situ or placed soil0.00moderatenone — impermeable steel wall; dewatering pumping may be neededsoft clay to dense granular; anchor zone must be competent4012.2103Tieback anchors or deadman anchors relieve cantilever bending; anchor at 0.2–0.4H from top; USACE free-earth and fixed-earth support methods; permanent ground anchors per PTI DC80.34moderate — anchor zone extends 0.7–1.0H behind wallmoderate — anchors provide redundancy but connections are failure points; detailed seismic analysis requireddeep excavation support; waterfront walls; seaport quay walls; permanent cuts > 15 ft
sheet_pilesheet_pile_cantileverpoor — corrugated steel faceany — wall retains in-situ or placed soil0.00fastnone — impermeable steel; drainage not a concern unless dewatering requiredsoft to medium cohesive or dense granular; passive resistance required185.551.5Steel sheet piling driven into ground; depth of embedment = 2.0–2.5× exposed height for cantilever; economical for H<15 ft; permanent corrosion coating or cathodic protection required for marine; USACE EM 1110-2-25043minimal — zero to 2 ft setbackpoor to moderate — tall cantilevers vulnerable to lateral spreading; keep H<15 ft in seismic zonestemporary excavations; waterfront bulkheads; cofferdams; small permanent cuts

This is a sample. Search the full retaining wall type selection dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE

Related data