Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Pcb Trace Current: external

ext 2oz 30C 3A to ext 3oz 30C 5A

PCB trace width vs. current carrying capacity per IPC-2221 Section 6.2 formula (external: I=0.048×ΔT^0.44×A^0.725; internal: I=0.024×ΔT^0.44×A^0.725). Covers external and internal PCB layers, copper weights 0.5–3 oz/ft², temperature rises 10–45°C, currents 0.5–10 A. Includes trace width in mils and mm, copper cross-section area, and trace resistance per inch.

Electrical Engineeringlayer type: external5 rowsPage 5 of 5
layer typerecord idcopper thickness mils (mil)copper weight oz (oz/ft2)cross section mils2 (mil2)current A (A)resistance mohm per inch (mohm/in)standardtemp rise C (C)trace width mils (mil)trace width mm (mm)
externalext 2oz 30C 3A2.74227.9531.07IPC-2221 Section 6.2; IPC-2152; Saturn PCB Calculator3010.20.259
externalext 3oz 10C 10A4.113314.48100.095IPC-2221 Section 6.2; IPC-2152; Saturn PCB Calculator1076.51.943
externalext 3oz 10C 5A4.113118.3750.25IPC-2221 Section 6.2; IPC-2152; Saturn PCB Calculator1028.80.731
externalext 3oz 20C 5A4.11377.2750.39IPC-2221 Section 6.2; IPC-2152; Saturn PCB Calculator2018.80.478
externalext 3oz 30C 5A4.11359.250.5IPC-2221 Section 6.2; IPC-2152; Saturn PCB Calculator3014.40.366