Pcb Trace Current: internal

PCB trace width vs. current carrying capacity per IPC-2221 Section 6.2 formula (external: I=0.048×ΔT^0.44×A^0.725; internal: I=0.024×ΔT^0.44×A^0.725). Covers external and internal PCB layers, copper weights 0.5–3 oz/ft², temperature rises 10–45°C, currents 0.5–10 A. Includes trace width in mils and mm, copper cross-section area, and trace resistance per inch.

Electrical Engineeringlayer_type: internal3 rows
layer typerecord idcopper thickness mils (mil)copper weight oz (oz/ft2)cross section mils2 (mil2)current A (A)notesresistance mohm per inch (mohm/in)temp rise C (C)trace width mils (mil)trace width mm (mm)
internalint_0p5oz_10C_0p5A0.6850.515.690.5IPC-2221 internal layer; I=0.024×dT^0.44×A^0.7251.91022.90.582
internalint_0p5oz_10C_1A0.6850.545.761IPC-2221 internal layer; I=0.024×dT^0.44×A^0.7250.651066.81.697
internalint_0p5oz_10C_2A0.6850.5133.712IPC-2221 internal layer; I=0.024×dT^0.44×A^0.7250.2210195.24.958

This is a sample. Search the full pcb trace current dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE