Explore the Engineering Database more efficiently by signing up for free. Sign up free
Cs-275-Dynamic — Gland Design Dynamic
- Seal Application
- Gland Design Dynamic
- Record Id
- Cs 275 Dynamic
- Backup Ring Pressure Psi (psi)
- 1,500
- Cs in (in)
- 0.275
- Cs MM (mm)
- 6.99
- Description
- Dynamic Reciprocating Gland Cs 0.275 in 400-Series
- Gland Depth Dynamic in (in)
- 0.239
- Gland Width in (in)
- 0.377
- Gland Width MM (mm)
- 9.58
- Groove Finish Ra Uin (microinch)
- 32
- Groove Finish Ra Um (um)
- 0.81
- Squeeze Pct Dynamic Max (%)
- 16
- Squeeze Pct Dynamic Min (%)
- 11
- Standard
- Parker Ord 5700; Global O-Ring Design Guide; ISO 3601-2:2016
Source: Parker ORD 5700; Global O-Ring Design Guide; ISO 3601-2:2016