Cs-210-Dynamic — Gland Design Dynamic
- Seal Application
- Gland Design Dynamic
- Record Id
- Cs 210 Dynamic
- Backup Ring Pressure Psi (psi)
- 1,500
- Cs in (in)
- 0.21
- Cs MM (mm)
- 5.33
- Description
- Dynamic Reciprocating Gland Cs 0.210 in 300-Series
- Gland Depth Dynamic in (in)
- 0.187
- Gland Width in (in)
- 0.283
- Gland Width MM (mm)
- 7.19
- Groove Finish Ra Uin (microinch)
- 32
- Groove Finish Ra Um (um)
- 0.81
- Squeeze Pct Dynamic Max (%)
- 14
- Squeeze Pct Dynamic Min (%)
- 8
- Standard
- Parker Ord 5700; Global O-Ring Design Guide; ISO 3601-2:2016
Source: Parker ORD 5700; Global O-Ring Design Guide; ISO 3601-2:2016