tap betareynolds numberCd (dimensionless)approach velocity factor E (dimensionless)beta ratio (dimensionless)expansion factor Y (dimensionless)permanent pressure loss pct (%)pipe diameter in (inch)tap typeuncertainty pct (%)
corner#0.7510,0000.65141.14220.751274corner1
corner#0.75100,0000.63351.14220.751274corner1
corner#0.751,000,0000.6271.14220.751276corner0.75

This is a sample. Search the full orifice plate coefficients dataset and 350+ more by creating a free account and accessing the database.