Orifice Plate Coefficients: corner#0.20

ISO 5167-2 orifice plate discharge coefficients (Cd) and flow measurement parameters per the Reader-Harris/Gallagher (1998) equation — corner taps, flange taps, and D-and-D/2 taps; beta ratio 0.10-0.75; Reynolds numbers 1e4-1e7

Mechanical Engineeringtap_beta: corner#0.203 rows
tap betareynolds numberCd (dimensionless)approach velocity factor E (dimensionless)beta ratio (dimensionless)expansion factor Y (dimensionless)permanent pressure loss pct (%)pipe diameter in (inch)tap typeuncertainty pct (%)
corner#0.2010,0000.59891.00160.21962corner0.75
corner#0.20100,0000.59731.00160.21964corner0.75
corner#0.201,000,0000.5971.00160.21966corner0.6

This is a sample. Search the full orifice plate coefficients dataset and 350+ more by creating a free account and accessing the database.