Orifice Plate Coefficients: corner#0.20
ISO 5167-2 orifice plate discharge coefficients (Cd) and flow measurement parameters per the Reader-Harris/Gallagher (1998) equation — corner taps, flange taps, and D-and-D/2 taps; beta ratio 0.10-0.75; Reynolds numbers 1e4-1e7
| tap beta | reynolds number | Cd (dimensionless) | approach velocity factor E (dimensionless) | beta ratio (dimensionless) | expansion factor Y (dimensionless) | permanent pressure loss pct (%) | pipe diameter in (inch) | tap type | uncertainty pct (%) |
|---|---|---|---|---|---|---|---|---|---|
| corner#0.20 | 10,000 | 0.5989 | 1.0016 | 0.2 | 1 | 96 | 2 | corner | 0.75 |
| corner#0.20 | 100,000 | 0.5973 | 1.0016 | 0.2 | 1 | 96 | 4 | corner | 0.75 |
| corner#0.20 | 1,000,000 | 0.597 | 1.0016 | 0.2 | 1 | 96 | 6 | corner | 0.6 |