Orifice Plate Coefficients: corner#0.55
ISO 5167-2 orifice plate discharge coefficients (Cd) and flow measurement parameters per the Reader-Harris/Gallagher (1998) equation — corner taps, flange taps, and D-and-D/2 taps; beta ratio 0.10-0.75; Reynolds numbers 1e4-1e7
| tap beta | reynolds number | Cd (dimensionless) | approach velocity factor E (dimensionless) | beta ratio (dimensionless) | expansion factor Y (dimensionless) | permanent pressure loss pct (%) | pipe diameter in (inch) | tap type | uncertainty pct (%) |
|---|---|---|---|---|---|---|---|---|---|
| corner#0.55 | 10,000 | 0.6226 | 1.044 | 0.55 | 1 | 65 | 4 | corner | 0.75 |
| corner#0.55 | 100,000 | 0.6155 | 1.044 | 0.55 | 1 | 65 | 4 | corner | 0.75 |
| corner#0.55 | 1,000,000 | 0.613 | 1.044 | 0.55 | 1 | 65 | 6 | corner | 0.6 |
This is a sample. Search the full orifice plate coefficients dataset and 350+ more by creating a free account and accessing the database.
Get started for FREE