Nuclear Decay Heat Curves: standard PWR

157680000 to 315360000

Decay heat power fraction vs time after shutdown for nuclear reactor design and spent fuel management. Covers U-235 thermal fission, U-238 fast fission, Pu-239 thermal fission, standard PWR (45 GWd/tHM), standard BWR (45 GWd/tHM), and MOX fuel per ANSI/ANS-5.1-2014. Time range: 1 second to 10 years. Includes dominant isotope contributors and 2-sigma uncertainty.

Nuclear Engineeringfuel type: standard PWR2 rowsPage 2 of 2
fuel typetime after shutdown sburnup GWd per tHM (GWd/tHM)decay heat fraction of operating power (dimensionless)dominant isotope contributorsenrichment pct (%)standarduncertainty pct 2sigma (%)
standard PWR157,680,000450.000346Cs-137+Sr-90+Cs-134+Am-2414.2ANS 5.1 20144
standard PWR315,360,000450.000202Cs-137+Sr-90+Am-241+Pu-2384.2ANS 5.1 20145