Explore the Engineering Database more efficiently by signing up for free. Sign up free

Uf-Pvdf-Sw-Ind — Uf

Membrane Type
Uf
Record Id
Uf Pvdf Sw Ind
Bacteria Log Removal Max
6
Bacteria Log Removal Min
4
Cleaning Frequency
Monthly
Flux Lmh Max (L/m2/h)
80
Flux Lmh Min (L/m2/h)
20
Flux Lmh Typical (L/m2/h)
40
Fouling Potential
Moderate
Material
Pvdf
Module Configuration
Spiral Wound
Mwco Daltons Max (Da)
100,000
Mwco Daltons Min (Da)
10,000
Parameter Group
Operating Parameters
Parameter Name
Ultrafiltration Pvdf Spiral Wound Industrial Process
Pore Size Um Max (um)
0.1
Pore Size Um Min (um)
0.005
Process Category
Industrial
Recovery Pct Max (%)
95
Recovery Pct Min (%)
80
Tmp Bar Max (bar)
5
Tmp Bar Min (bar)
0.3
Turbidity Rejection Pct
99.9
Virus Log Removal Max
3
Virus Log Removal Min
2