Explore the Engineering Database more efficiently by signing up for free. Sign up free

Uf-Ps-Hf-Leachate — Uf

Membrane Type
Uf
Record Id
Uf Ps Hf Leachate
Bacteria Log Removal Max
6
Bacteria Log Removal Min
4
Cleaning Frequency
Weekly
Flux Lmh Max (L/m2/h)
40
Flux Lmh Min (L/m2/h)
10
Flux Lmh Typical (L/m2/h)
20
Fouling Potential
Very High
Material
Polysulfone
Module Configuration
Hollow Fiber
Mwco Daltons Max (Da)
100,000
Mwco Daltons Min (Da)
10,000
Parameter Group
Operating Parameters
Parameter Name
Ultrafiltration Polysulfone Hollow Fiber Leachate Pretreatment
Pore Size Um Max (um)
0.1
Pore Size Um Min (um)
0.01
Process Category
Leachate Treatment
Recovery Pct Max (%)
90
Recovery Pct Min (%)
70
Tmp Bar Max (bar)
3
Tmp Bar Min (bar)
0.2
Turbidity Rejection Pct
99.9
Virus Log Removal Max
3
Virus Log Removal Min
2
UF — record id UF_PS_HF_LEACHATE · parameter name Ultrafiltration polysulfone hollow fiber leachate pretreatment · fouling potential very_high · process category leachate_treatment · flux lmh max 40 L/m2/h | Membrane Filtration | Engineering Database