Explore the Engineering Database more efficiently by signing up for free. Sign up free

Ro-Pa-Tfc-Sw-Sw — Ro

Membrane Type
Ro
Record Id
Ro Pa Tfc Sw Sw
Bacteria Log Removal Max
7
Bacteria Log Removal Min
6
Cleaning Frequency
Monthly
Flux Lmh Max (L/m2/h)
18
Flux Lmh Min (L/m2/h)
8
Flux Lmh Typical (L/m2/h)
12
Fouling Potential
High
Hardness Rejection Pct Max (%)
99.8
Hardness Rejection Pct Min (%)
99
Material
Pa Tfc
Module Configuration
Spiral Wound
Mwco Daltons Max (Da)
0.0001
Mwco Daltons Min (Da)
0.0001
NaCl Rejection Pct Max (%)
99.8
NaCl Rejection Pct Min (%)
99
Organics Rejection Pct Max (%)
99.8
Organics Rejection Pct Min (%)
99
Parameter Group
Operating Parameters
Parameter Name
Reverse Osmosis Pa Tfc Spiral Wound Seawater Desalination
Process Category
Seawater
Recovery Pct Max (%)
50
Recovery Pct Min (%)
40
Tds Rejection Pct Max (%)
99.8
Tds Rejection Pct Min (%)
99
Tmp Bar Max (bar)
70
Tmp Bar Min (bar)
40
Turbidity Rejection Pct
99.9
Virus Log Removal Max
7
Virus Log Removal Min
6
RO — record id RO_PA_TFC_SW_SW · parameter name Reverse osmosis PA TFC spiral wound seawater desalination · process category seawater · fouling potential high · recovery pct min 40 % | Membrane Filtration | Engineering Database