Explore the Engineering Database more efficiently by signing up for free. Sign up free

Ro-Pa-Tfc-Pharm — Ro

Membrane Type
Ro
Record Id
Ro Pa Tfc Pharm
Bacteria Log Removal Max
7
Bacteria Log Removal Min
6
Cleaning Frequency
Weekly to Monthly
Flux Lmh Max (L/m2/h)
20
Flux Lmh Min (L/m2/h)
12
Flux Lmh Typical (L/m2/h)
16
Fouling Potential
Moderate
Hardness Rejection Pct Max (%)
99.7
Hardness Rejection Pct Min (%)
98
Material
Pa Tfc
Module Configuration
Spiral Wound
Mwco Daltons Max (Da)
0.0001
Mwco Daltons Min (Da)
0.0001
NaCl Rejection Pct Max (%)
99.5
NaCl Rejection Pct Min (%)
97
Organics Rejection Pct Max (%)
99.7
Organics Rejection Pct Min (%)
97
Parameter Group
Operating Parameters
Parameter Name
Reverse Osmosis Pa Tfc Pharmaceutical Ultrapure Water
Process Category
Pharmaceutical Water
Recovery Pct Max (%)
95
Recovery Pct Min (%)
85
Tds Rejection Pct Max (%)
99.5
Tds Rejection Pct Min (%)
97
Tmp Bar Max (bar)
25
Tmp Bar Min (bar)
8
Turbidity Rejection Pct
99.9
Virus Log Removal Max
7
Virus Log Removal Min
6
RO — record id RO_PA_TFC_PHARM · parameter name Reverse osmosis PA TFC pharmaceutical ultrapure water · process category pharmaceutical_water · fouling potential moderate · recovery pct min 85 % | Membrane Filtration | Engineering Database