Repeatability — Length Gauge Block
- Measurement Type
- Length Gauge Block
- Uncertainty Source
- Repeatability
- Confidence Level Pct (%)
- 95
- Coverage Factor K
- 2
- Distribution
- Normal
- Divisor
- 1
- Expanded Uncertainty K2
- 0.0002
- Expanded Uncertainty Unit
- MM
- Standard
- ASME B89.1.9-2002; ISO 3650:1998
- Standard Uncertainty Unit
- MM
- Standard Uncertainty Value
- 0.0001
- Uncertainty Type
- Type a
Source: ASME B89.1.9-2002; ISO 3650:1998