Explore the Engineering Database more efficiently by signing up for free. Sign up free
Viscosity-Effect — Flow Turbine Meter
- Measurement Type
- Flow Turbine Meter
- Uncertainty Source
- Viscosity Effect
- Confidence Level Pct (%)
- 95
- Coverage Factor K
- 2
- Distribution
- Normal
- Divisor
- 2
- Expanded Uncertainty K2
- 0.4
- Expanded Uncertainty Unit
- Pct Flow
- Standard
- Aga Report No. 7:2006; Oiml R 49
- Standard Uncertainty Unit
- Pct Flow
- Standard Uncertainty Value
- 0.2
- Uncertainty Type
- Type B
Source: AGA Report No. 7:2006; OIML R 49