Explore the Engineering Database more efficiently by signing up for free. Sign up free

Discharge-Coefficient — Flow Orifice Plate

Measurement Type
Flow Orifice Plate
Uncertainty Source
Discharge Coefficient
Confidence Level Pct (%)
95
Coverage Factor K
2
Distribution
Normal
Divisor
2
Expanded Uncertainty K2
1
Expanded Uncertainty Unit
Pct Flow
Standard
ISO 5167-1:2022; Aga Report No. 3 Part 1
Standard Uncertainty Unit
Pct Flow
Standard Uncertainty Value
0.5
Uncertainty Type
Type B

Source: ISO 5167-1:2022; AGA Report No. 3 Part 1

flow_orifice_plate — uncertainty source discharge_coefficient · standard ISO 5167-1:2022; AGA Report No. 3 Part 1 · standard uncertainty value 0.5 · expanded uncertainty k2 1 · expanded uncertainty unit pct_flow | Measurement Uncertainty | Engineering Database