Explore the Engineering Database more efficiently by signing up for free. Sign up free
Combined-Standard-Uncertainty — Flow Orifice Plate
- Measurement Type
- Flow Orifice Plate
- Uncertainty Source
- Combined Standard Uncertainty
- Confidence Level Pct (%)
- 95
- Coverage Factor K
- 2
- Distribution
- Normal
- Divisor
- 1
- Expanded Uncertainty K2
- 1.12
- Expanded Uncertainty Unit
- Pct Flow
- Standard
- ISO 5167-1:2022 Annex A; Gum Jcgm 100:2008
- Standard Uncertainty Unit
- Pct Flow
- Standard Uncertainty Value
- 0.56
- Uncertainty Type
- Combined
Source: ISO 5167-1:2022 Annex A; GUM JCGM 100:2008