Insulation R Values: rubber_silicone
Insulation R-values and thermal conductivity data from NIST SRD 81 — covers fiberglass, foam, cellulose, mineral wool, and other building insulation materials
| material id | record id | date | delta t (F) | delta x (in) | density (lb/ft3) | description | form | k w mk (W/mK) | manufacturer | material | mean temp (F) | r value per inch (ft2hF/BTU/in) | rsi per inch (m2K/W/in) | test method | trade name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| rubber_silicone | 1232 | 10/4/1960 | 9.46 | 0.4969 | 75.87 | Commercial silicone rubber, ½ in. | Slab | 1.6955 | Dow Corning Corp. | Rubber, Silicone | 117.95 | 0.085065 | 0.014981 | ASTM C 177 | Silastic® |
| rubber_silicone | 1233 | 10/6/1960 | 9.26 | 0.4895 | 77.02 | Commercial silicone rubber, ½ in. | Slab | 1.7117 | Dow Corning Corp. | Rubber, Silicone | 60.28 | 0.08426 | 0.014839 | ASTM C 177 | Silastic® |
| rubber_silicone | 1234 | 10/7/1960 | 9.51 | 0.4967 | 75.9 | Commercial silicone rubber, ½ in. | Slab | 1.6961 | Dow Corning Corp. | Rubber, Silicone | 117.96 | 0.085035 | 0.014976 | ASTM C 177 | Silastic® |
This is a sample. Search the full insulation r values dataset and 300+ more by creating a free account and accessing the database.