material idrecord iddatedelta t (F)delta x (in)density (lb/ft3)descriptionformk w mk (W/mK)materialmean temp (F)r value per inch (ft2hF/BTU/in)rsi per inch (m2K/W/in)standardtest method
plywood64712/7/194823.21.2833Two 5/8 in. samples glued together (79 % RH)Board0.9087Plywood70.450.1587190.027952NIST SRD 81 APIASTM C 177
plywood64912/9/194824.051.283Two 5/8 in. samples glued together (79 % RH)Board0.8743Plywood39.430.1649640.029052NIST SRD 81 APIASTM C 177
plywood6521/3/194923.281.285534.8Two 5/8 in. samples glued together (79 % RH)Board0.8947Plywood54.210.1612030.028389NIST SRD 81 APIASTM C 177
plywood6581/17/194923.651.255834.8Two 5/8 in. samples glued together, sanded, aluminum paintedBoard0.7892Plywood70.980.1827520.032184NIST SRD 81 APIASTM C 177