Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Insulation R Values: perlite

1042 to 636

Insulation R-values and thermal conductivity data from NIST SRD 81 — covers fiberglass, foam, cellulose, mineral wool, and other building insulation materials

Civil Engineeringmaterial id: perlite10 rowsPage 1 of 2
material idrecord iddatedelta t (F)delta x (in)density (lb/ft3)descriptionformk w mk (W/mK)manufacturermaterialmean temp (F)r value per inch (ft2hF/BTU/in)rsi per inch (m2K/W/in)standardtest methodtrade name
perlite10428/8/195622.821.01665.882Specimens placed in wood framesLoose0.3897Atlantic Perlite Co.Perlite128.070.37010.065178NIST SRD 81 APIASTM C 177Panacalite (?)
perlite3275/22/194318.491.01510.6Fine powder placed in containerLoose0.4533Perlite94.560.3181730.056034NIST SRD 81 API
perlite3285/31/194319.081.0178.7Granules, 3 mm, placed in containerLoose0.4332Perlite95.070.3329360.058633NIST SRD 81 API
perlite3788/31/194420.471.00053.52Expanded, placed in wood framesLoose0.2975Silbrico CorporationPerlite99.830.48480.085378NIST SRD 81 APIRyolex®
perlite5272/23/194822.840.99999.15Ryolex®, heavyLoose0.3689Silbrico CorporationPerlite71.10.3909670.068853NIST SRD 81 APIASTM C 177Ryolex®
perlite63111/4/194823.480.97899.36Specimens placed in wood frames (TUC-96C)Loose0.3741Perlite70.740.3855330.067896NIST SRD 81 APIASTM C 177
perlite63211/5/194823.260.979614.8Specimens placed in wood frames (TUC-96D)Loose0.4725Perlite70.630.3052440.053757NIST SRD 81 APIASTM C 177
perlite63311/8/194824.060.980518.65Specimens placed in wood frames (TUC-96E)Loose0.5089Perlite71.370.2834110.049912NIST SRD 81 APIASTM C 177
perlite63411/9/194823.270.980424.76Specimens placed in wood frames (TUC-107)Loose0.5875Perlite70.620.2454940.043234NIST SRD 81 APIASTM C 177
perlite63611/12/194821.870.975414.5Specimens placed in wood frames (TUC-96D)Loose0.5194Perlite128.970.2776820.048903NIST SRD 81 APIASTM C 177

What else is in Engineering Database

Related data