Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Insulation R Values: glass

1470 to 2112

Insulation R-values and thermal conductivity data from NIST SRD 81 — covers fiberglass, foam, cellulose, mineral wool, and other building insulation materials

Civil Engineeringmaterial id: glass4 rowsPage 3 of 3
material idrecord iddatedelta t (F)delta x (in)density (lb/ft3)descriptionformk w mk (W/mK)manufacturermaterialmean temp (F)r value per inch (ft2hF/BTU/in)rsi per inch (m2K/W/in)standardtest methodtrade name
glass147011/15/196313.230.9659138.7AnnealedBlock7.3685Corning Glass WorksGlass30.780.0195740.003447NIST SRD 81 APIASTM C 177Pyrex® 7740
glass21106/25/198024.060.947138.46Block6.6445Corning Glass WorksGlass75.620.0217060.003823NIST SRD 81 APIASTM C 177Pyrex® 7740
glass21116/27/198023.90.947138.46Block6.7977Corning Glass WorksGlass98.670.0212170.003737NIST SRD 81 APIASTM C 177Pyrex® 7740
glass21126/30/198022.980.947138.46Block6.8479Corning Glass WorksGlass126.060.0210620.003709NIST SRD 81 APIASTM C 177Pyrex® 7740

What else is in Engineering Database

Related data