material idrecord iddatedelta t (F)delta x (in)density (lb/ft3)descriptionformk w mk (W/mK)manufacturermaterialmean temp (F)r value per inch (ft2hF/BTU/in)rsi per inch (m2K/W/in)standardtest methodtrade name
fiberboard wood9578/26/195434.231.308615.4Roof insulationBoard0.3769Armstrong Cork Co.Fiberboard, Wood73.460.3826690.067392NIST SRD 81 APIASTM C 177Temlok®
fiberboard wood9609/1/195424.220.975518.5Insulation boardBoard0.3913Armstrong Cork Co.Fiberboard, Wood73.90.3685870.064912NIST SRD 81 APIASTM C 177Temlok®
fiberboard wood9619/2/195424.40.974313.2Insulation boardBoard0.3548Armstrong Cork Co.Fiberboard, Wood74.030.4065050.07159NIST SRD 81 APIASTM C 177Temlok®
fiberboard wood9681/29/195533.851.503514.69Wood fiber, feltedBoard0.3395Johns ManvilleFiberboard, Wood74.360.4248240.074816NIST SRD 81 APIASTM C 177Roofinsul®
fiberboard wood9732/10/195533.81.477415.27Wood fiber, feltedBoard0.342Johns ManvilleFiberboard, Wood74.460.4217190.074269NIST SRD 81 APIASTM C 177Roofinsul®
fiberboard wood9742/11/195523.960.960915.19Wood fiber, feltedBoard0.3368Johns ManvilleFiberboard, Wood73.80.428230.075416NIST SRD 81 APIASTM C 177Roofinsul®
fiberboard wood9772/24/195523.860.923116.02Asphalt coating (both faces), split in halfBoard0.3536Johns ManvilleFiberboard, Wood73.580.4078840.071833NIST SRD 81 APIASTM C 177Roofinsul®