Civil Engineeringmaterial id: cellular polyvinyl chloride3 rows
material idrecord iddatedelta t (F)delta x (in)density (lb/ft3)descriptionformk w mk (W/mK)manufacturermaterialmean temp (F)r value per inch (ft2hF/BTU/in)rsi per inch (m2K/W/in)standardtest methodtrade name
cellular polyvinyl chloride15133/5/196425.961.09654.643PVC foamBoard0.2466B.F. GoodrichCellular Polyvinyl Chloride54.270.5848660.103001NIST SRD 81 APIASTM C 177
cellular polyvinyl chloride16769/7/196624.341.06482.949PVC foamBoard0.2201Cellular Polyvinyl Chloride74.980.6552840.115402NIST SRD 81 APIASTM C 177Vinycel
cellular polyvinyl chloride16779/8/196624.251.12681.894PVC foamBoard0.183Cellular Polyvinyl Chloride74.630.7881310.138798NIST SRD 81 APIASTM C 177Vinycel