Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Insulation R Values: cellular polyurethane

1804 to 1954

Insulation R-values and thermal conductivity data from NIST SRD 81 — covers fiberglass, foam, cellulose, mineral wool, and other building insulation materials

Civil Engineeringmaterial id: cellular polyurethane7 rowsPage 6 of 6
material idrecord iddatedelta t (F)delta x (in)density (lb/ft3)descriptionformk w mk (W/mK)manufacturermaterialmean temp (F)r value per inch (ft2hF/BTU/in)rsi per inch (m2K/W/in)standardtest methodtrade nameuncertainty
cellular polyurethane180410/29/196925.121.02972.205Board0.1135Upjohn Co., CPR DivisionCellular Polyurethane39.651.270730.223789NIST SRD 81 APIASTM C 177CPR Urethane
cellular polyurethane18141/15/197024.780.98251.625Board0.1243Reed Paint Co.Cellular Polyurethane39.051.1603210.204344NIST SRD 81 APIASTM C 177CPR Urethane
cellular polyurethane18194/8/197025.610.9851.736Board0.1399Cellular Polyurethane40.081.0309360.181558NIST SRD 81 APIASTM C 177
cellular polyurethane182711/30/197025.650.8881.853Board0.1353Cellular Polyurethane40.51.0659860.187731NIST SRD 81 APIASTM C 177
cellular polyurethane18524/12/197325.021.06852.232Board0.1323Apache Co.Cellular Polyurethane69.081.0901580.191988NIST SRD 81 APIASTM C 177
cellular polyurethane19145/27/197524.131.00472.032Specimens have many voidsBoard0.1383Cellular Polyurethane75.141.0428630.183659NIST SRD 81 APIASTM C 177
cellular polyurethane19547/14/197723.280.95723.827Polyurethane foam and aluminum facers, creases in facersBoard0.1427Cellular Polyurethane74.181.0107070.177996NIST SRD 81 APIASTM C 1771