Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Insulation R Values: cellular polystyrene extruded

784 to 905

Insulation R-values and thermal conductivity data from NIST SRD 81 — covers fiberglass, foam, cellulose, mineral wool, and other building insulation materials

Civil Engineeringmaterial id: cellular polystyrene extruded4 rowsPage 4 of 4
material idrecord iddatedelta t (F)delta x (in)density (lb/ft3)descriptionformk w mk (W/mK)manufacturermaterialmean temp (F)r value per inch (ft2hF/BTU/in)rsi per inch (m2K/W/in)standardtest methodtrade name
cellular polystyrene extruded78410/16/195021.970.98231.441Board0.328Dow Chemical Co.Cellular Polystyrene, Extruded120.680.4397190.077439NIST SRD 81 APIASTM C 177Styrofoam®
cellular polystyrene extruded9036/3/195323.591.00671.792Pore diameter: 0.25 mm to 0.5 mmBoard0.2886Dow Chemical Co.Cellular Polystyrene, Extruded71.860.499750.088011NIST SRD 81 APIASTM C 177Styrofoam®
cellular polystyrene extruded9046/4/195324.331.00661.792Pore diameter: 0.25 mm to 0.5 mmBoard0.2631Dow Chemical Co.Cellular Polystyrene, Extruded40.450.5481870.096541NIST SRD 81 APIASTM C 177Styrofoam®
cellular polystyrene extruded9056/8/195322.081.00411.797Pore diameter: 0.25 mm to 0.5 mmBoard0.3401Dow Chemical Co.Cellular Polystyrene, Extruded126.630.4240750.074684NIST SRD 81 APIASTM C 177Styrofoam®