Heat exchanger fouling factors (fouling resistance) for various fluid services — single-fluid TEMA values plus combined (total dirt) fouling resistance for common shell-and-tube service pairs from Perry's CEH Table 11-3

Mechanical Engineeringservice id: tubular dowtherm vapor tall oil deriv1 row
service idfluid servicefouling factor combined hhf (h·ft2·°F/Btu)fouling factor max m2k w (m2K/W)fouling factor min m2k w (m2K/W)hx typeshell sidestandardtube side
tubular dowtherm vapor tall oil derivDowtherm vapor / Tall oil and derivatives (condensing)0.0040.0007040.000704shell-and-tubeDowtherm vaporPerry's Chemical Engineers' Handbook, 8th Ed., Table 11-3Tall oil and derivatives