Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free
Home/Reference Data/Hx Fouling Factors/cracking and coking units streams

Hx Fouling Factors: cracking and coking units streams

Heat exchanger fouling factors (fouling resistance) for various fluid services — single-fluid TEMA values plus combined (total dirt) fouling resistance for common shell-and-tube service pairs from Perry's CEH Table 11-3

Mechanical Engineeringservice id: cracking and coking units streams1 row
service idfluid servicefouling factor max m2k w (m2K/W)fouling factor min m2k w (m2K/W)standard
cracking and coking units streamsCracking and Coking Units streams0.000350.00035TEMA Standards, 9th Ed., Table RGP-T-2.4